codeGen error in {worker}-impl.vhd when declaring TimeInterface in OWD.

Description

Sent to Kulp:

The app worker FAILS to compile because the wrapper (OCP) wti record signal is assigned to the inward facing wti_in signal. This suggests that the time_client should be instanced at the worker level to perform the OCP/inward conversion, as is with the wsi_slave, wsi_master, & wci.

Kulp Response:
We made a choice a while ago to NOT put the time clients into the worker wrappers.
The primary reason is that time clients could be different depending on the clocking situation on the chip and also we had the notion of a "lite" and "heavy" version that could be chosen later.

Environment

Discovered when building for ML605.

Assignee

Unassigned

Reporter

Adam Ponchak

Labels

None

Components

Priority

Major